![]() ![]() Many Applications, One Chiller – YCAL chillers offer a variety of energy, sound, and mechanical configurations to suit your many application needs.More Building…Less Chiller – YCAL chillers are lighter and smaller than competitive units, which minimizes your installed cost and maximizes your usable space. ![]() Reduced Total Cost of Ownership – Excellent energy efficiency, high reliability, and easy maintenance minimize your cost of ownership.Environmental Responsibility Is Standard – YORK® chillers, with zero-ODP HFC-410A refrigerant and up to 50% less refrigerant charge, make you the leader in environmental design.More Building…Less Chiller – YCAL chillers are lighter and smaller than competitive units, which minimizes your installed cost and maximizes your usable space. ![]() Environmental Responsibility Is Standard – YORK® chillers, with zero-ODP HFC-410A refrigerant and up to 50% less refrigerant charge, make you the leader in environmental design. Our YCAL Air-Cooled Chillers feature a single-point power connection for reduced wiring costs, industry leading environmentally friendly design, high energy efficiency, and a light, small unit to maximize your usable space. Operation above 46.1☌ requires Optional High Ambient kit (Maximum recommended operating temperature is 54.4☌). Operation below -3.9☌ requires the Optional Low Ambient kit (Minimum recommended operating temperature is -17.8☌). This air-cooled chiller uses scroll compressor technology and is a reliable, completely self-contained unit that is designed for easy, low-cost outdoor installation. Minimize the total cost of ownership for your air-conditioning application with the YORK® YCAL Air-cooled Scroll Chiller. Standard units cannot be operated below 4.4☌ leaving chilled liquid temperature. Power supply: 3PH-480V-60HZ, Allowing the voltage fluctuate ☑0%, allow phase voltage difference ☒%, Allow the frequency range ☐.2Hz.At YORK® by Johnson Controls, we help you minimize the total cost of ownership for your air conditioning application with our YCAL Air-Cooled Scroll Chiller. Chilled water work allowed temperature range: 5℃~35℃ (41☏ ~95☏). Control Accuracy ☏ ☓.6 Cooling capacity based on 5℃(41℉) leaving coolant and 35℃(95℉) ambient air. ℉ 122 Power Supply 3PH-480V-60HZ Max Amp A 83 Total Power Input HP 67 Power Supply Cable Diameter mm² 3x35+2x16 Safety Protection Device Overload, Inverse Phase, High/Low Pressure, Water Flow, Water Level & Anti-Freeze Protection Refrigerant Type R410A Charge Lbs 40 Compressor Start Mode Direct start Type Scroll Type Qty 4 HP 13.5x4 RLA (Rated Load Amp) 15.1x4 LRA(Locked Rotor Amp) 125x4 Fan Qty 4 Type External Rotar Axial Fan Power HP 1.13x4 Current A 1.27x4 LRA A 8x4 Volume Air Flow CFM 29964 Condenser Type MCHE Subcooling ℉ 9 Heat Rejection BTU/h 49600 Evaporator Type SS304 Shell and Cu Tubes Superheat ℉ 9 Heat Rejection BTU/h 369900 Cooled Water Flow GPM 82 Water Pressure Drop PSI ≤12 Energy Adjust Mode 100%-50%-25%-0% Throttling Device Mode Thermal Expansion Valve Pipe Water Inlet MNPT 3” Water Outlet MNPT 3” Water Pump Flow GPM 82 Head PSI 50.8 LRA A 48.6 Power HP 5.50 Water Tank Capacity Gal 90.6 Sound Pressure at 1 meter Dba 75 Programming Controller Display LCD Display Controller Microcomputer Controller Temp.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |